Previously QBC Diagnostics and the Drucker Company

The QBC Autoread Plus Dry Hematology System is a reliable and rugged complete blood count analyzer used by thousands of practitioners around the globe. A cost-effective and virtually maintenance free system, the Autoread Plus provides point-of-care CBCs in just 7 minutes.

Part Number : 428605

Online Promotional Price: $4,545.00

QBC Autoread Plus Dry Hematology System

Click on above image to view full picture

More Views

QBC Autoread Plus: Literature

Interested in learning more about the Autoread? The following is an archive of currently available documents concerning the QBC Autoread Plus:

Autoread Plus Product Literature

BrochureBrochure
A full-color brochure describing the many features and benefits of the Autoread Plus technology.

 

 

SpecificationSheetSpecification Sheet
A document containing all specifications for the Autoread Plus, including size, electrical specifications, environmental specifications, and more.

 

ProductDescriptionList Product Description List
A list of all configurations and accessories currently available for the Autoread Plus, including part numbers.

 

OperatorsManualOperator's Manual
The complete operator's manual for the Autoread Plus.
English | Deutsch | Français

 


What is Dry Hematology?What is Dry Hematology?

A one page overview explaining the principle of dry hematology and the many benefits it offers.

 

 

QBC Centrifuge Product Literature

SpecificationSheetSpecification Sheet
A document containing all specifications for the QBC Centrifuge.


 

OperatorsManualOperator's Manual
The complete operator's manual for the QBC Centrifuge.


 

QBC Autoread Plus: Features

The QBC Autoread Plus has a decade long proven track record of being extremely reliable in the world's harshest environments. From medical tents in Iraq and Afghanistan to research facilities in Antarctica, the Autoread Plus has proven that it can handle the worst conditions imaginable.

The Autoread Plus Dry Hematology System offers a durable, cost-effective option for conducting hematology testing in virtually any setting. The Autoread Plus System, which consists of a reader, a centrifuge, and an external printer, uses patented dry hematology technology to deliver a 9-parameter, 2 part differential.This results in many benefits for the user:

Eliminating Liquid Reagents

Unlike competing products, the Autoread uses no liquid reagents. That saves lab space for the user, since there is no need to store bottles of reagents. There is also less maintenance required, as there is no need for cleaning or replacing internal parts. The only waste products generated by the Autoread are the QBC tubes, which are easier to dispose of than dangerous biohazard reagent chemicals.

Durability and Portability

The Autoread System is the most durable CBC analyzer on the market, as its dry hematology technology and hard plastic frame make it suitable for conducting testing in even the harshest conditions. Because of the unique QBC dry reagent technology, the Autoread can be transported and quickly deliver results in any location. Setup time is minimal, as the Autoread is always ready to provide fast, accurate hematology analysis.

Easy to Use

Learning to use the Autoread is easy. After preparing a blood sample using a QBC tube, simply centrifuge the tube for five minutes at 12,000 RPM and then place it in the reader. Results will print out automatically using an attached printer. Office personnel can be easily trained to use the Autoread, making the most of any office's limited resources.

9-Count CBC

The Autoread measures nine important CBC hematological parameters from venous or capillary blood samples: hematocrit, hemoglobin, MCHC (mean corpuscular hemoglobin concentration), platelet count, white blood cell count, granulocyte count and percentage, and lymphocyte/monocyte count and percentage. Clinical trials have demonstrated that the accuracy and precision of the Autoread System correlate well to accepted standard methods.

Reliability

The Autoread is exceptionally reliable. The system is permanently calibrated during manufacturing, so the user needs to only run a basic daily calibration check to verify satisfactory performance. Because of the unique QBC dry technology, the Autoread can deliver reliable results using only a fingerstick blood sample.

QBC Autoread Plus: Technology


The technology at the heart of the Autoread is a process known as Quantitative Buffy Coat (QBC) analysis.Dry Hematology Video


This process, is based on the physiological phenomenon in which the differing densities of blood components will cause them to separate into layers when centrifuged at a high rate of speed. Click on the image to the right to watch a video on the Dry Hematology technology.


QBC tubes, including the many varieties available for the Autoread, take advantage of this phenomenon in two ways. First, through the use of a small plastic float with the approximate density of platelets and white blood cells (the "buffy coat"), those usually small layers can be physically expanded for greater analysis. Second, a metachromatic acridine orange stain coating the inside of the tubes stain lymphocytes and monocytes green, platelets yellow, and granulocytes orange, making the difference between layers visible, even to the naked eye. Once a sample has been centrifuged, the Autoread utilizes a dual light source and optical detector to read the results of the test. Once complete, the Autoread prints the results to an attached external printer.

Jump to a section:

CLIA

Controls and Diagnostics

Sample Collection and Analysis

Printing

Troubleshooting

CLIA

Is the Autoread considered CLIA waived?
Currently, all of the QBC Systems are moderately complex.

Controls and Diagnostics

How often do I have to run external controls on the QBC Autoread Plus?
Traditional quality controls consists of running at least two levels of external control material each day of patient testing.

My controls arrived warm (ice packs were melted); can I still use the controls?
The controls may work in the short term, but may be prone to early degradation. If the controls are warm, a replacement set can be requested by calling Drucker Diagnostics Technical Support at +1-866-265-1486 (U.S. only).

Sample Collection and Analysis

What type of sample is required for QBC Autoread testing?
Whole blood samples collected from either a capillary fingerstick or a venous blood draw (EDTA purple top tube).

How much blood is required to test on the Autoread systems?
The amount of blood is dependent upon the tube type being used:

  • Accutube - 70µl
  • Standard Capillary - 60µl
  • Standard Venous - 111µl

What tube types can be used with the Autoread System?
Accutube, Standard Capillary, or Standard Venous.

What collection method should be used for the different tube types?
The collection method is dependent upon the tube type being used:

  • Accutube - fingerstick collection or venous blood (EDTA tube)
  • Standard Capillary - fingerstick collection
  • Standard Venous - venous blood (EDTA tube)

How long can a venous sample be stored prior to testing on the Autoread System?
This is dependent on each individual tube type. Check the tube package insert for each specification.

Can a sample be processed more than once on the Autoread?
Yes, once centrifuged, the QBC tubes can be analyzed more than one time. The tube must be stored in an upright position and is stable at room temperature for up to four hours. QBC tubes should NOT be centrifuged more than one time.

How can I get results from my QBC Autoread into other external systems (e.g., EMR, LIS, etc.)?
We recommend contacting Apex Healthware. Apex Healthware is a developer of affordable HL7 interfaces and laboratory information systems.

Printing

What printers are compatible with the QBC Autoread Plus?
Brother HL-5240, Brother HL-5250DN & Brother HL-5340D. Other printers may work with the systems if they use the Epson language (ESC/P2/LQ).

The Autoread ran the test but the results are not printing. Why?
Power off the printer and follow the instructions in the Operator's Manual for resetting the print format. Power on the printer and test the cal rod or a sample.

Can I reprint the results on the QBC Autoread?
If the tube is still in the instrument, press the "Next" button.

Troubleshooting

What causes a "Sample Error 20" or "Buffy Coat Unreadable" errors?
These errors are generally sample related. Ensure that venous samples are well mixed prior to loading the QBC Tube. Invert the venous tube 12-15 times prior to loading the tube or 5 minutes on a mechanical rotator. For capillary samples, proper collection technique is extremely important. Warming the finger, using a blade lancet, wiping off the first drop of blood, and refraining from excessive squeezing of the collection area will yield a good sample.  Certain illnesses and disease processes may contribute to these errors as well. If an illness or disease is thought to be the cause of the error, the patient should be tested via another method.

Contact Technical Support for any questions.

I am seeing discrepancies between the results on the QBC and the results from the reference lab. Why?
The results from two different CBC methodologies will rarely be exactly the same. Confirm that the results are from the same sample. If one set of results is from a capillary sample and the other set is from a venous sample, the results could vary significantly. If the results vary between multiple capillary or multiple venous samples, it could be due to differences in the times of collections technique.

If the results are from the same venous sample, remix the venous tube at least 12-15 inversions prior to sampling. Confirm that the test was performed within the acceptable time limit and that the venous sample was stored according to the manufacturer's recommendation.

Can I run Veterinary samples on the Autoread?
It is not recommended to run animal samples on the instruments designed for human testing. IDEXX has the QBC Veterinary instruments with the appropriate software and tubes for animal samples. Contact IDEXX at +1-800-248-2483.

Interested in the financial benefits of the Autoread Plus? This financial calculator can help you to determine the monthly profit you will derive from using the Autoread Plus system, as well as a break even calculation.

Expected Return on Investment (ROI) Calculator

Cost Information

  • QBC Autoread Plus Dry Hematology System

QBC Autoread Plus: Service

For all service inquiries, please contact the Drucker Diagnostics Technical Service Department at +1-866-265-1486 (U.S. only) or support@druckerdiagnostics.com. Our Technical Support Representatives are available Monday - Friday, 8:30 a.m. - 5:00 p.m. (EST). Otherwise, contact your nearest Drucker Diagnostics office for assistance. To locate a service center near you, please click here.

Limited Warranty

Diagnostics includes a 1-year limited warranty from the date of original shipment on all Autoread Plus Analyzers and QBC Centrifuges. In the unlikely event that an Autoread Plus Analyzer or QBC Centrifuge needs repair due to defects in materials and workmanship, the warranty covers all parts and labor needed to repair the Autoread Plus at no cost to the user. The Autoread Plus printer is covered by the terms of its own manufacturer's warranty. Please consult Appendix D of the Autoread Operator's Manual for more details on the terms of the warranty. 

Beyond the initial one-year warranty, QBC Diagnostics, Inc., offers two additional annual service agreement programs, the Single Swap and Double Swap Service Agreements, each of which may be contracted for 1 or 2 years. With the Single Swap Service Agreement, QBC Diagnostics, Inc., will simply replace the user's broken Autoread Plus system with a refurbished system, at no additional cost to the user. With a Double Swap system, QBC Diagnostics, Inc., will provide a temporary replacement Autoread Plus while your Autoread Plus system is repaired and returned to you. For more details on these service agreements, please consult the Annual Service Agreement Programs document and the Service Agreement Renewal form.

Troubleshooting

The Autoread Plus contains almost no user replaceable parts. If any portion of the instrument fails to operate properly, DO NOT ATTEMPT TO PERFORM ANY SERVICE OR REPAIR, unless specifically listed below. Refer service problems to the Technical Service Department of Drucker Diagnostics at +1-866-265-1486 (U.S. only) or support@druckerdiagnostics.com. Our Technical Support Representatives are available Monday - Friday, 8:30 a.m. - 5:00 p.m. (EST). Otherwise, contact your nearest Drucker Diagnostics office for assistance. In some instances, a customer can perform minor corrective actions to fix smaller problems with the Autoread Plus or its component parts. Consult the following for information on these specific instances:

QBC Autoread Plus Analyzer
There are no customer-serviceable internal parts on the Autoread Plus Analyzer. Calibration adjustments, failure of internal lamps, or mechanical-electrical problems must be referred to a qualified Drucker Diagnostics service technician. The only replacement parts currently available for the Analyzer are external parts such as the power pack, line cords, and, in extreme cases, the software cartridge. Consult the Product Description List for ordering information on these parts.

Autoread Plus Analyzer Power Pack
There are no customer-serviceable parts on the Power Pack. The unit, however, is protected by internal overload and thermal fuses. If the Power Pack fails to supply DC outputs to the Analyzer, check the electrical line to the receptacle that supplies current to the Power Pack before requesting service. To order a replacement power pack or line cord, consult the Product Description List for ordering information on these parts.

QBC Centrifuge
For information on service and repair for the QBC Centrifuge, please consult the operator's manual.

QBC Pipetter
Blood leakage or failure of the QBC Pipetter to aspirate blood to the correct level may indicate that the Pipetter barrel is worn or should be replaced. To order a replacement power pack or line cord, consult the Product List page for ordering information on these parts.

Drucker Diagnostics, Inc., has also developed the following series of videos that walk users through the basics of the Autoread Plus system:

     
What's Included? Installing the Autoread Plus Installing the Autoread Plus Centrifuge
A detailed video which highlights all of the
components that are shipped with the Autoread Plus system.
Installing the Autoread Plus is easy with this informative video. A few connections is all it takes to install the Centrifuge to the Autoread Plus.
     
Sample Collection Centrifuge Operation Operation

Learn how to fill a tube using the finger stick method.

Learn how to load tubes and operate the Centrifuge. Basic operation of the Autoread Plus is detailed in this short video.
 
QBC Synthetic Control Mixing Demonstration
A detailed video which highlights all of the components that are shipped with the Autoread Plus system.

 

Click the following sections for more information on CLIA requirements for the Autoread Plus Dry hematology analyzer:

What is CLIA?

Quality Requirements for Moderately Complex Tests

Written Procedure Manual

Proficiency Testing

Personnel Training and Evaluation

Laboratory Director

Other Positions

Quality Assessment

Internal Quality Checks

External Quality Checks

CLIA Inspections

Application for CLIA Certification

What is CLIA?

CLIA is an acronym for Clinical Laboratory Improvement Amendments. It sets forth uniform quality standards for laboratories and applies to all entities that perform tests for health purposes on human specimens. CLIA requirements are based on the complexity of tests performed (waived, moderate, or high).

QBC hematology systems, such as the Autoread Plus, are considered moderate complexity test systems, and therefore must meet quality requirements for moderately complex testing.

Quality Requirements for Moderately Complex Tests

Written Procedure Manual

A procedure manual is a detailed sequence of activities showing how the test procedure is to be performed. It breaks down the test procedure one step at a time. You may utilize the Autoread Plus Operator's Manual as your procedure manual if it is your policy to do so. Please ensure personnel are informed that they must follow the procedure as stated in the Operator's manual for performing the test. The procedure must be approved and signed by the Laboratory Director.

Proficiency Testing

CLIA requires that you participate in a Proficiency Test Program. These programs monitor the performance of your test system. Participants will receive five unknown samples, three times per year. Samples are to be treated in the same manner as patient specimens. The results are evaluated and comparisons made to other laboratories within your Peer group; laboratories using the same analyzer and tube type. Below is a listing of Proficiency Test Providers and a chart percentage of QBC participants submitting results according to each provider.

American Proficiency Institute (API)
800-333-0958 www.api-pt.com

American Academy of Family Physician's (AAFP)
800-274-2237 www.aafp.org

American College of Physicians (PT division-Medical Laboratory Evaluation-MLE)
800-338-2746 www.acponline.org

College of American Pathologists (CAP)
800-323-4040 www.cap.org

American Association of BioAnalysts (AAB)
800-234-5615 www.aab.org

Personnel Training and Evaluation

For a link to CLIA personnel qualifications: www.cms.hhs.gov/cmsforms/downloads/cms209.pdf

Laboratory Director

CLIA specifies that a physician (MD or DO) serving as Laboratory Director must have at least one year experience supervising moderately complex testing OR complete a 20 credit course. This course can be completed on-line at www.medicine.uiowa.edu/cme/clia/ orwww.cola.org/labu.html. The Lab Director can also attend a 2.5 day workshop provided by COLA (www.cola.org for dates and times).

Additionally, individuals with a Bachelor's degree and 2 years laboratory experience PLUS 2 years supervisory experience, or a Master's degree and 1 year experience PLUS 1 year supervisory experience also qualify to direct a moderately complex laboratory.

Other Positions

Moderately complex laboratories also have three other positions specified by CLIA:
  1. Clinical Consultant (Qualified Laboratory Director)
  2. Technical Consultant (Qualified Laboratory Director)
  3. Testing analyst (high school diploma and documented training)
* a single person may fill the position of Lab Director, Clinical, and Technical Consultant.

Quality Assessment

CLIA requires that the following quality standards be tested and documented on moderately complex systems:
  1. Specimen ID and Integrity
  2. Patient Confidentiality
  3. Personnel competency assessment
  4. Proficiency Testing
  5. Test requesting
One means of testing these quality standards is through the use of internal and external quality checks, as appropriate.

External Quality Checks

Liquid controls are available for the Autoread Plus through Drucker Diagnostics. Traditional quality controls consists of running at least two levels of external control material each day of patient testing.

Drucker Diagnostics also offers an online Inter-Lab Quality Control (ILQC) program to provide monthly peer comparisons with statistical evaluation of your results. To access this program, please click here.

CLIA Inspections

CLIA requires inspections every two years. The inspections are non-punitive unless there if a failure to correct deficiencies.

Laboratories may also choose another CLIA approved accrediting agency, including COLA (www.cola.org), CAP (www.cap.org), or JCAHO (www.jcaho.org) to conduct the inspections. These organizations will assist you in preparing your laboratory for inspection, including support and training. Fees vary, so please visit each individual site for further information on the services they provide.

Application for CLIA Certification

To apply for CLIA certification or to change Certificate Type, please consult the following website:www.cms.hhs.gov/cmsforms/downloads/cms116.pdf

Please note that your completed CLIA application should be forwarded to the address of the local State Agency for the state in which your laboratory resides. You should also contact this State Agency for additional forms that may be necessary to complete the registration process. For a listing of contact information by state, please go to the following website: https://www.cms.gov/Regulations-and-Guidance/Legislation/CLIA/Downloads/CLIASA.pdf

States Requiring certification:

CA, CT, FL, HI, ID, MD, NV, PA, and WA

QBC Autoread Plus: Testimonials QBC systems have been in use globally for over 25 years with active installations on every continent, including Antarctica. There are over 15,000 active hematology systems worldwide and at least 1,500 fluorescent microscopy systems using our Malaria, Parasitology, and TB kits. If you would like references for any of our innovative solutions from users near you, please contact us.


 

"Following the earthquake in (January 2010), our clinic lab was inundated with new patients. As a result, we needed a solution for quickly and effectively diagnosing anemia and other diseases. Someone told me about the Autoread Plus, and made a donation so that we could buy the system. I cannot begin to tell you the difference it is making in the accuracy and efficiency of our diagnostics. It is especially marvelous because there is not a tremendous amount of blood to be disposed of. Plus, our charts are such that the lab results can be nicely displayed."
Berry Rice, Director, Clinique Esperance et Vie, Terrier Rouge, Haiti
www.BethlehemMinistry.org


 

"With the QBC Autoread, we have been able to increase our overall lab productivity with only minimal maintenance and an impressive amount of convenience. The design of the system in terms of its size and portability is well-suited for rural district hospitals such as ours and enables us to think about not only hospital-based laboratory tests, but also the possibility of carrying our lab equipment to regional sites where their lab capacity may not be as robust as our own, thereby helping to create partnerships and increase health services more broadly throughout the region."
Dan Schwarz, Executive Director, Nyaya Health, Nepal
www.nyayahealth.org


 

"The QBC Autoread Plus is a durable workhorse. We've used the unit for about 3 years in remote jungle locations and our newer stationary health clinic in the Bolivian Amazon. The unit provides valid and reliable results, and requires relatively low maintenance. It is also extremely user-friendly. Although we do not have a high patient volume (we average roughly 10 patients per day), the QBC Autoread Plus has outlasted nearly all of our other laboratory equipment. I highly recommend this product for analysis of hematocrit, hemoglobin, platelet count, and differential cell counts."
Michael Gurven, Integrative Anthropological Sciences, Unit Chair, University of California, Santa Barbara
www.unm.edu/~tsimane/